3a. Installing the LCU (Internal)
The following procedure is to prepare the LCU for internal
installation. For an external installation, please skip to step 3b.
To prepare the LCU for installation:
1. Open the coolant valve on the top of the Aquagate LCU
assembly with a coin or a broad screwdriver.
2. Decide the location in which you want to install then LCU,
then figure out the length the pipes will need to be in order to
run from the water block on the CPU to the LCU. This must
be done before filling the tank with liquid coolant.
3. Fit the non-leaking plugs into the free ends of the water pipes.
(Place the LCU near the side panel of chassis to make it
easier.) Next, connect them to the non-leaking pipe
connectors at the back of the Aquagate LCU.
4. Secure the pipe clip tightly around the neck where the non-
leaking plug mates with the water pipe.